{"product_id":"tj-4a-sl0104-1a-laboratorial-syringe-pump","title":"TJ-4A\/SL0104-1A Laboratorial Syringe Pump","description":"\u003cp\u003e\u003cspan\u003eProduct Introduction\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTJ-4A\/SL0104-1A is syringe pumps, mainly used in veterinary medicine application. Drive unit has small size and lightweight, can be mounted on stereotaxic apparatus and micromanipulator. With 0.5μL~50μLmicro syringe, the pump can be used for intracellular injection, biological chemical dosing and cell separation in vitro with small volume in picoliters. The pump has wide range of linear speed (3μm\/min\u003c\/span\u003e～\u003cspan\u003e128mm\/min), can meet different speed requirements. The drive unit SL0104-1A, designed based on 30mm stroke syringes, has smallest size and lightest weight (only 258g). The drive unit SL0107-1A can accept most of manual glass syringes within 50μL volume in the market. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Function\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003e1) Work Mode: infusion, withdrawal, infusion\/withdrawal, withdrawal\/infusion, continuous\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e2) Flow rate calibration: improve flow rate accuracy\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e3) Display: volume, flow rate or linear speed can be selected and displayed on the LCD.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e4) Power-off memory: When power on, operator can choose to continue previous operation or not.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e5) Fast forward\/ backward: infuse or withdraw liquid at full speed\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e6) Syringe user-defined: can store four user-defined syringe IDs.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e7) State signal output: 2 output signals (OC gate signal) to indicate start\/stop and direction.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e8) 3 input signals (TTL signal) to control start\/stop, fast forward and fast backward.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e9) Communication Interface: RS485\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"801\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\"\u003e\u003cspan\u003eDrive unit quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"593\" colspan=\"2\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStroke of drive unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e40mm \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSyringe volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e0.5-50μL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePusher advance per step\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e3.048µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e3.048μm\/min~ 128.016mm\/min(flow rate= linear speed* section area of the barrel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear speed resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e3.048µm\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear travel accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eerror≤±0.5% (when travel ≥30% of the drive unit stroke)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin flow rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e0.054nL\/min(0.5μL syringe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax flow rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e213.3μL\/min(50μL syringe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear force\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e＞10N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController outline dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e178mm*112mm*67mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e0.5kg \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrive unit outline dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e130mm*35mm*34mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrive unit weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e258g \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eAC 90V-260V\/10W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e0℃～40℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"208\"\u003e\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e＜80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOther Parameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"706\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"140\" rowspan=\"3\"\u003e\u003cspan\u003eSyringe pump\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"162\" rowspan=\"3\"\u003e\u003cspan\u003eSyringe Volume\u003cbr\u003e (μL)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\" rowspan=\"3\"\u003e\u003cspan\u003eID\u003cbr\u003e （mm）\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"309\" colspan=\"2\"\u003e\u003cspan\u003eRef.flowrate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"174\" rowspan=\"2\"\u003e\u003cspan\u003eMin\u003cbr\u003e nL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\" rowspan=\"2\"\u003e\u003cspan\u003eMax      \u003cbr\u003e μL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"140\" rowspan=\"7\"\u003e\u003cspan\u003eTJ-4A\/SL0104-1A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e0.5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e0.15\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e0.0539\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e2.26\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e0.2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e0.0958\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e4.02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e0.35\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e0.293\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e12.32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e0.5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e0.598\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e25.1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e0.8\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e1.53\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e64.35\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e25\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e1.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e2.9\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e121.66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"162\"\u003e\u003cspan\u003e50\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cspan\u003e1.4567\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"174\"\u003e\u003cspan\u003e5.08\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e\u003cspan\u003e213.3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Langer Instruments","offers":[{"title":"TJ-4A\/SL0104-1A","offer_id":42694564511975,"sku":"","price":2207.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/1691\/1591\/products\/TJ-4A.jpg?v=1646899944","url":"https:\/\/www.langerpump.com\/de\/products\/tj-4a-sl0104-1a-laboratorial-syringe-pump","provider":"Langer Instruments","version":"1.0","type":"link"}